Sitting Hyperbaric Chamber Solutions for Clinical & Wellness Facilities

A sitting hyperbaric chamber eliminates crawl-in tube entry while delivering verified 1.3–2.0 atmospheres absolute (ATA) hyperbaric oxygen therapy (HBOT). Shanghai Baobang Medical Equipment Co., Ltd. (MACY-PAN) manufactures the rigid HP800S (2.0 ATA) and HP800M (1.3–1.5 ATA) hard-shell sitting hyperbaric chambers under ISO 13485 and CE (2014/68/EU PED) quality systems for clinics and wellness centers across over 126 countries.

  • Compare 2.0 ATA single-user (HP800S) and 1.3–1.5 ATA two-person (HP800M) hard-shell cabins.
  • Evaluate sliding-door accessibility, reclining seating, and 20°C water-cooled air conditioning.
  • Ensure that you check door width, floor loading and scope of OEM branding before sending your quote request.
MACY-PAN HP800S sitting hard-shell hyperbaric chamber with sliding entry door and integrated control cabinet
MACY-PAN HP800S rigid sitting hyperbaric chamber with integrated control console and sliding door.

HP800S: 2.0 ATA Single-User Cabin

1386 × 780 × 1853 mm carbon-steel hull, 2196 × 957 mm footprint, 468 kg weight.

HP800M: 1.3–1.5 ATA 1–2 Person Cabin

1800 × 857 × 2053 mm composite hull, 2610 × 957 mm footprint, 750 kg weight.

ISO 13485 & CE 2014/68/EU Certified

Over 17 years of manufacturing across 3 Shanghai bases (~130,000 sq ft) with a 1-year warranty.

Sitting Hyperbaric Chamber Configurations

Claustrophobia and panic inside horizontal tubes cause patients to abort sessions before reaching target pressure. Because elderly, post-surgical, and mobility-limited clients struggle to climb into horizontal cylinders, MACY-PAN engineers the HP800 sitting hyperbaric series around upright walk-in accessibility and an internal high-back reclining chair. Validated under ISO 13485 and CE 2014/68/EU pressure vessel controls, our spacious hard-shell chambers turn patient refusal into completed daily HBOT sessions.

HP800S vs. HP800M application selection

HP800S (1 Person, 2.0 ATA Hard-Shell)

Built for medical clinics, neurology centers, and sports recovery facilities requiring a higher pressure level up to 2.0 ATA. The 780 mm cabin width and 2196 × 957 mm footprint (2.1 m²) fit compact treatment rooms while providing a thickened carbon-steel body and aluminum sliding door.

2.0 ATA · 1 Person 780 mm Width 2196 × 957 mm (2.1 m²)
HP800S (1 Person, 2.0 ATA Hard-Shell)

HP800M (1–2 People, 1.3–1.5 ATA Hard-Shell)

Engineered for wellness centers, longevity lounges, and assisted-care clinics where an attendant or second user accompanies the client. Its 1800 × 857 × 2053 mm spacious cabin pairs a double-layer metal composite body with a transparent acrylic sliding door.

1.3–1.5 ATA · 1–2 People 1800 × 857 × 2053 mm
HP800M (1–2 People, 1.3–1.5 ATA Hard-Shell)

Facility deployment scenarios

Matching sitting hyperbaric chamber models to facility requirements

Facility type Recommended model Operating pressure & occupancy Selection driver
Rehabilitation & neurology clinic HP800S 2.0 ATA · 1 person Walk-in sliding door and reclining seat for wheelchair-transfer accessibility.
Sports medicine & athletic facility HP800S 2.0 ATA · 1 person High-pressure oxygen delivery (10 L/min at 93%+) in a 2.1 m² room footprint.
Commercial wellness & longevity center HP800M 1.3–1.5 ATA · 1–2 people Acrylic sliding door and two-person cabin reduce claustrophobic anxiety.
Assisted pediatric or elder care HP800M 1.3–1.5 ATA · 1–2 people Allows a caregiver inside the oxygen chamber during pressurization.

Contrary to the common assumption that a higher pressure level is always better, a 2.0 ATA protocol is not always required for general wellness recovery, and a soft-shell unit is not necessarily lower in five-year clinic operating cost. Multi-user wellness centers often select the 1.3–1.5 ATA HP800M because dual occupancy and a full-view acrylic door match their client comfort profile.

HP800S vs. HP800M Technical Specifications

Commercial doorway width and floor load block rigid chamber delivery when buyers order from incomplete spec sheets. The root cause is ignoring the difference between cabin hull width (780 mm vs. 857 mm) and total installed footprint including the external auxiliary console. MACY-PAN obliterates the risk of ordering by reporting paired dimensional, weight, and electrical parameters from our ISO 13485 factory test record for each sitting hyperbaric chamber.

“A vertical sitting hyperbaric chamber must hold pressure stability across thousands of compression cycles while fitting through standard commercial corridors, which is why we engineered the HP800S hull to 780 mm width in one-piece carbon steel.”

MACY-PAN Engineering Team, Shanghai Baobang Medical Equipment Co., Ltd.
Interior of MACY-PAN HP800S sitting hyperbaric chamber showing high-back adjustable reclining chair and control panel
HP800 series interior featuring flame-retardant high-back adjustable reclining chair, internal touchscreen, and dual oxygen delivery.
  • Both models feature dual interior/exterior synchronized smart touchscreens that allow the technician outside or user inside to pressurize and depressurize the cabin.
  • Handle dual emergency pressure relief valves so depressurization can occur with no electrical power.

MACY-PAN HP800S and HP800M verified catalog specifications

Parameter HP800S (Single-Person 2.0 ATA) HP800M (1–2 Person 1.3–1.5 ATA)
Operating pressure rating 2.0 ATA (atmospheres absolute) 1.3–1.5 ATA (atmospheres absolute)
Occupancy capacity 1 person (reclining chair) 1–2 people (reclining seating)
Chamber hull dimensions (L × W × H) 1386 × 780 × 1853 mm 1800 × 857 × 2053 mm
Total installation footprint (L × W) 2196 × 957 mm (approx. 2.1 m²) 2610 × 957 mm (approx. 2.5 m²)
Chamber net weight 468 kg 750 kg
Chamber body material Thickened carbon steel Thickened carbon steel + double-layer metal composite
Entry door material High-strength aluminum sliding door High-strength transparent acrylic sliding door
Oxygen concentrator package PSA molecular sieve, 10 L/min, 93%+ oxygen purity PSA molecular sieve, 10 L/min, 93%+ oxygen purity
Air conditioning & ventilation 20°C water-cooled AC, 45 L/min air flow 20°C water-cooled AC, 45 L/min air flow
Power supply & isolation protection AC 220V/110V, 600–1100W (1600W input) + 36V isolation transformer AC 220V/110V, 600–1100W (1600W input) + 36V isolation transformer

Measure the clear opening of your corridor and doorway with our Sitting Chamber Footprint & Doorway Calculator prior to placing an order.

Sitting Chamber Footprint & Doorway Calculator

One-Piece Vertical Steel Hull vs. Conventional Chambers

Soft-shell zipper teeth and TPU seams degrade under repeated daily clinic cycles, while bolted square chambers suffer from corner stress concentration and seal leakage. Because pressure vessels experience uniform hoop stress only on curved geometries, MACY-PAN fabricates the HP800 hard-shell hyperbaric chamber with a one-piece vertical steel cylinder and precision sliding door. Certified to CE 2014/68/EU (PED), ASME, and ISO 13485 standards, this structure eliminates zipper replacement downtime and sustains up to 2.0 ATA hard-shell performance.

Engineering trade-off comparison across four hyperbaric chamber architectures

Chamber architecture Pressure levels & entry Structural & operational trade-off
  • MACY-PAN HP800 sitting hard-shell
    1.3–1.5 ATA or 2.0 ATA · Sliding door
    One-piece steel hull with reclining chair; requires 780–857 mm doorway clearance and 468–750 kg floor support.
  • Soft-shell sitting chamber
    1.3 ATA (up to 1.5 ATA) · Dual zipper
    Lower initial soft hyperbaric chamber price and light weight, but zipper wear and lower pressure limits restrict clinical protocols.
  • Horizontal hard-shell tube
    1.5–2.0 ATA · Sliding hatch
    High pressure capability, but crawl-in supine posture triggers claustrophobia and occupies longer floor length.
  • Bolted modular square chamber
    1.3–1.5 ATA · Hinged door
    Walk-in room feel, but flat panels and bolted gaskets concentrate corner stress and increase leak maintenance.
MACY-PAN HP800 hard-shell sitting hyperbaric chamber with one-piece vertical steel cylinder and sliding door

When a rigid sitting chamber is the wrong choice

A rigid hard-shell sitting chamber is not interchangeable with a portable soft-shell tent when a buyer needs upstairs residential delivery through a 680 mm doorway or frequent vehicle transport. The trade-off is physical mass: 468 kg (HP800S) to 750 kg (HP800M) of thickened carbon steel buys you 2.0 ATA structural longevity and sliding-door convenience, whereas a portable TPU chamber trades pressure ceiling for fold-up portability.

Cross-model benchmark and replacement enquiries

When clinics compare or upgrade from an OxyRevo, OxyRevo Space60, or another 1.3 ATA soft-shell unit to a medical-grade 2.0 ATA hard-shell sitting chamber, send us the current room dimensions, doorway width, and target treatment option. Our engineers will verify whether the HP800S or HP800M fits your existing space and electrical circuit.

Facility Installation, Cooling, and OEM Customization Scope

Heat buildup and compressor noise ruin 60-to-90-minute treatment comfort when chambers rely on uncooled ambient air compression. Because adiabatic compression raises cabin temperature and humidity, MACY-PAN integrates an environmentally friendly 20°C water-cooled air conditioning system (45 L/min air flow), a 10 L/min PSA oxygen concentrator (93%+ purity), and a 36V isolation transformer inside a standalone plug-and-play cabinet. Tested to RoHS3 and TÜV material safety standards, the cabin stays cool, quiet, and electrically isolated throughout every session.

Included subsystem scope, facility requirements, and OEM customization options

Subsystem / scope area Standard HP800 specification Facility / OEM customization boundary
Oxygen delivery system 10 L/min PSA molecular sieve concentrator (93%+ oxygen) with diffused + mask delivery Follow FDA oxygen safety and fire-prevention protocols; never introduce open flames or ungrounded electronics.
Thermal & acoustic control 20°C water-cooled AC with dual-circulation airflow (45 L/min) and acoustic cabin trim Maintain room ventilation around the external integrated machine cabinet.
Electrical & low-voltage safety AC 220V/110V, 600–1100W (1600W input power) with 36V isolation transformer Specify local voltage/frequency (110V/60Hz or 220V/50Hz) and plug standard at order.
Interior & exterior finishes Sandblasted Class A baked paint, eco-friendly PU leather trim, non-slip floor, reclining chair OEM customization available for exterior paint color, logo branding, upholstery color, and flooring pattern.
Mobility & rigging 4 high-strength universal casters mounted under the chamber base Verify narrowest doorway (≥780 mm for HP800S, ≥857 mm for HP800M) and elevator depth before shipment.

Sitting Hyperbaric Chamber Room Footprint, Model Comparison & Clinic Power Tools

Verify doorway clearance, compare HP800S (2.0 ATA, 468 kg) and HP800M (1.3–1.5 ATA, 750 kg) catalog specifications, and estimate daily clinic electrical consumption and oxygen delivery volume before submitting your quotation request.

Sitting Hyperbaric Chamber Room Footprint & Doorway Clearance

Check doorway width and room floor clearance against MACY-PAN HP800S (780 mm cabin width, 2196 × 957 mm footprint) and HP800M (857 mm cabin width, 2610 × 957 mm footprint) catalog dimensions. This geometric check does not replace a site rigging survey of corridor turns, elevators or floor loading.

Worked example

Example: an 850 mm doorway with a 3000 × 1800 mm room gives HP800S (780 mm cabin width, 2196 × 957 mm footprint) a +70 mm doorway margin, +804 mm length margin, and +843 mm width margin.

HP800S vs HP800M Sitting Hyperbaric Chamber Comparison

Compare catalog specifications between the single-person HP800S (2.0 ATA, 2196 mm length, 468 kg) and the 1–2 person HP800M (1.5 ATA max, 2610 mm length, 750 kg). Use this comparison to evaluate pressure protocol versus cabin occupancy and floor loading.

Worked example

Example: comparing HP800S (Model A) to HP800M (Model B) shows a -0.5 ATA maximum pressure difference, +414 mm footprint length difference, +282 kg chamber weight difference, and a 1.6 weight ratio.

Sitting Hyperbaric Chamber Clinic Power & Oxygen Estimator

Estimate daily operating hours, annual electrical consumption and oxygen delivery volume from your planned clinic schedule using the HP800 catalog 1.6 kW (1600W) input power and 10 L/min oxygen concentrator rating. This worksheet does not predict clinic revenue or payback.

Worked example

Example: 6 sessions/day at 60 minutes (6 hours/day) over 300 days at 1.6 kW uses 2,880 kWh/year (432 currency units/year at 0.15/kWh) and delivers 3,600 L/day of oxygen at 10 L/min.

Sitting Hyperbaric Chamber FAQs

The common horizontal tube chamber necessitates the patient to crawl into a closed, lying position that produces confinement anxiety in claustrophobic target users. The MACY-PAN HP800 series is a vertical cabin with wide sliding door and high-back reclining chair. The patient walks or transfers in on wheelchair, and reads or works inside while taking an upright position, and controls pressurization on the internal panel.

Choose the HP800S if your clinical protocols require up to 2.0 ATA pressure in a compact 2196 × 957 mm single-person footprint with an aluminum sliding door. Choose the HP800M if you run a wellness center, recovery lounge, or assisted-care facility where 1.3–1.5 ATA pressure, two-person seating, and a full-view transparent acrylic sliding door improve client comfort.

The HP800S chamber hull measures 1386 × 780 × 1853 mm, requiring a clear doorway opening wider than 780 mm. The two-person HP800M hull measures 1800 × 857 × 2053 mm, requiring a clear opening wider than 857 mm. Both models roll on four high-strength universal casters; always measure door frames, corridor turns, and elevator depth before shipment.

Soft-shell sitting chambers use flexible TPU fabric and dual zipper closures, limiting operating pressure to 1.3–1.5 ATA and requiring periodic zipper and bladder maintenance under heavy commercial turnover. Hard-shell chambers like the HP800S and HP800M use thickened carbon steel and metal composite hulls with rigid sliding doors, sustaining up to 2.0 ATA (HP800S) and long-term multi-shift clinic durability.

An external integrated machine cabinet houses a 10 L/min PSA molecular sieve oxygen concentrator (delivering 93%+ oxygen purity via dual diffused and mask oxygen delivery) alongside an environmentally friendly 20°C water-cooled air conditioner (45 L/min air flow). This keeps the cabin cool and ventilated without placing high-voltage compressor motors inside the pressurized space.

The HP800 series operates on AC 220V or 110V with 600–1100W rated power (1600W input power) and includes an isolation transformer that limits internal electrical systems to 36V safe low voltage. Dual manual emergency pressure relief valves allow immediate decompression in the event of a building power outage.

MACY-PAN manufactures hyperbaric chambers under ISO 13485 (medical device quality management), ISO 9001, CE (2014/68/EU Pressure Equipment Directive), and ASME standards, with TÜV-tested interior material safety, RoHS3 compliance, and PICC product liability insurance. When purchasing for regulated clinical treatment of specific medical conditions in the United States, buyers should verify whether their protocol requires an FDA-cleared chamber under product code CBF and follow FDA hyperbaric safety guidance.

Total cost is driven by model selection (HP800S 2.0 ATA vs. HP800M 1.3–1.5 ATA), hull and door materials, OEM paint or upholstery customization, voltage configuration, and destination freight. Every MACY-PAN HP800 package includes the rigid chamber cabin, reclining seat, integrated PSA oxygen concentrator, 20°C water-cooled AC, isolation transformer, and a 1-year warranty with lifetime maintenance support.

Yes. With over 17 years of HBOT manufacturing experience and three Shanghai production bases (~130,000 sq ft), we provide tailored OEM and ODM production for distributors and clinic chains. You can customize the exterior baked-paint color, Logo, eco-friendly PU wall line, and non-slip flooring.

Factory Selection Support

Need a hyperbaric chamber matched to your room, pressure target, and compliance documents?

MACY-PAN helps clinics, wellness centers, distributors, and home buyers compare soft-shell, hard-shell sitting, and professional-grade lying chambers before quotation. Send your intended use, available space, country, and preferred ATA range, and our team will recommend a practical model path.

2007HBOT manufacturing since
126+countries shipped to
1.3-2.0ATA chamber range